呼吸内镜智能清洗消毒质量光学检测系统的护理质控标准研究
CSTR:
作者:
作者单位:

漯河市第七人民医院

作者简介:

通讯作者:

中图分类号:

基金项目:


Research on nursing quality control standards for optical detection system of intelligent cleaning and disinfection quality of respiratory endoscopy
Author:
Affiliation:

The Seventh People’s Hospital of Luohe

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 针对呼吸内镜清洗消毒质量依赖人工目测、缺乏客观标准的问题,本研究研发基于光学成像的智能检测系统并建立相应质控标准。方法 构建集成高分辨率内窥镜相机、多光谱光源与深度学习(deep learning,DL)算法的内镜洗消光学检测系统。纳入2025年1月至2025年6月漯河市第七人民医院呼吸内镜中心60条BF-Q170型呼吸内镜,随机分为实验组和对照组,每组各30条。所有内镜均完成标准化全自动洗消后,实验组采用智能系统评估,对照组采用人工目测评估;比较两组污染物检出率、单条内镜评估平均耗时、评估者间一致性及微生物检测合格率。结果 实验组对蛋白质、血液残留及生物膜的检出率均高于对照组(均P<0.05)。实验组单条内镜评估平均耗时显著短于对照组(P<0.001);对照组2名评估者的一致性仅为中等水平,而智能检测系统结果稳定。实验组微生物检测合格率显著高于对照组(P=0.045)。结论 该智能检测系统可实现呼吸内镜洗消质量的快速、客观、高敏感度评估,自动完成合格判定与不合格样本拦截,整体性能优于传统人工目测;以此建立的质控标准可形成有效质控闭环,为内镜洗消的标准化与数字化管理提供技术支持。

    Abstract:

    Objective To solve the problem that the quality of cleaning and disinfection of respiratory endoscope depends on manual visual inspection and lacks objective standards, this research developed an intelligent detection system based on optical imaging and established corresponding quality control standards. Methods An endoscope disinfection optical detection system integrating highresolution endoscope camera, multi-spectral light source and deep learning (DL) algorithm was constructed. From January 2025 to June 2025, 60 BF-Q170 type respiratory endoscopes were included in the respiratory endoscopy center of The Seventh People’s Hospital of Luohe. They were randomly divided into the experimental group and the control group, with 30 units in each group. After all endoscopes were fully and automatically disinfected according to the standard procedures, the experimental group was evaluated by intelligent system, and the control group was evaluated by manual visual inspection. The detection rates of the two groups of pollutants, the average time spent on each endoscopic examination, the consistency among assessors, and the qualified rate of microbial testing were compared. Results The detection rates of protein, blood residue and biofilm in the experimental group were higher than those in the control group (all P<0.05). Moreover, the average time spent on each endoscopic examination in the experimental group was significantly shorter than that of the control group (P<0.001). The consistency of the two assessors in the control group was only at a moderate level, while the results of the intelligent detection system were stable. In addition, the qualified rate of microbial testing in the experimental group was significantly higher than that in the control group (P=0.045). Conclusion This intelligent detection system can achieve rapid, objective and highly sensitive assessment of the cleaning and disinfection quality of respiratory endoscopes. It automatically completes the determination of qualified samples and the interception of unqualified samples. Its overall performance is superior to that of traditional manual visual inspection. The quality control standard established by this system forms an effective closed loop of quality control, which provides technical support for standardization and digital management of endoscopic disinfection.

    参考文献
    相似文献
    引证文献
引用本文

韩颖.呼吸内镜智能清洗消毒质量光学检测系统的护理质控标准研究[J].生物医学工程学进展,2026,(4):98-101